GE Security's Picture Perfect™ Flags and Values, Picture Perfect 1.5-2.0

This table shows the meanings and value meanings for all of the bit fields in the GE Security CASI Picture Perfect database.


Bit Meaning Bit Number Meaning When 0 Meaning When 1
alarm.flags
  Micro internal use only

 

0

 

Off

 

On

 

  Online

 

1

 

No

 

Yes

 

  Schedule Inhibit

 

2

 

No

 

Yes

 

  Auto Reset Outputs

 

3

 

No

 

Yes

 

  Manual Reset Outputs

 

4

 

No

 

Yes

 

  Duration Reset Outputs

 

5

 

No

 

Yes

 

  Immediate Reset Input

 

6

 

No

 

Yes

 

  Immediate Dial Required

 

7

 

No

 

Yes

 

area.flags
  Logical State

 

0

 

Offline

 

Online

 

  Physical

 

1

 

Disabled

 

Enabled

 

  Shunting

 

2

 

Disabled

 

Enabled

 


Scheduling

 

3

 

Enabled

 

Disabled

 

  APB Enforcement

 

4

 

Normal

 

Passive

 

badge.flags
  Keypad Response

 

0

 

Disabled

 

Enable

 

  Card Trace

 

1

 

Disabled

 

Enabled

 

  Limited Usage

 

2

 

Reserved

 

Exhausted

 

  Tour Badge

 

3

 

No

 

Yes

 

  Temporary Badge*

 

4

 

No

 

Yes

 

inputs.flags
  Normally Closed

 

0

 

No (Normally Open)

 

Yes (Normally Closed)

 

  Input Enabled

 

1

 

No

 

Yes

 

input_group.flags
  Not Used

 

0

 

Not Used

 

Not Used

 

  Input Group State

 

1

 

Disabled

 

Enabled

 

  Open Condition

 

2

 

Ignored

 

Detected

 

  Short Condition

 

3

 

Ignored

 

Detected

 

  Broadcast State Changes

 

4

 

No

 

Yes

 

output.flags
  Normally Open

 

0

 

No

 

Yes

 

  Output Enabled

 

1

 

No

 

Yes

 

  Reset On Duration

 

2

 

No

 

Yes

 

  Reset On Input

 

3

 

No

 

Yes

 

permission.flags
  None

 

0

 

No

 

Yes

 

  Read Only - Show Number

 

1

 

No

 

Yes

 

  Read Only - Hide Number

 

2

 

No

 

Yes

 

  Issue - Show Number

 

3

 

No

 

Yes

 

  Issue - Hide Number

 

4

 

No

 

Yes

 

reader.type
  Badge Rdr

 

0

 

No

 

Yes

 

  Badge and Keypad

 

1

 

No

 

Yes

 

  Keypad Only Rdr

 

2

 

No

 

Yes

 

  Badge or Keypad

 

3

 

No

 

Yes

 

  ABP In Rdr

 

4

 

No

 

Yes

 

  APB Out Rdr

 

5

 

No

 

Yes

 

  For Future Use

 

6

 

0

 

 

  T/A In and Out

 

7

 

No

 

Yes

 

  T/A In Rdr

 

8

 

No

 

Yes

 

  T/A Out Rdr

 

9

 

No

 

Yes

 

  Authorization Required

 

10

 

No

 

Yes

 

  No Authorization Required

 

11

 

No

 

Yes

 

reader.flags
  Logical State

 

0

 

Offline

 

Online

 

  Physical State

 

1

 

Disabled

 

Enabled

 

  Shunting

 

2

 

Disabled

 

Enabled

 

  Scheduling

 

3

 

Enabled

 

Disabled

 

  Toggle

 

4

 

No

 

Yes

 

  Limited Usage

 

5

 

Disabled

 

Enabled

 

  Elevator Reader

 

6

 

No

 

Yes

 

routing.flags
  Monitor

 

0

 

No

 

Yes

 

  History

 

1

 

No

 

Yes

 

  Printer

 

2

 

No

 

Yes

 

door.flags
  State

 

0

 

Locked

 

Unlocked

 

  Scheduling

 

1

 

Enabled

 

Disabled

 

  Held Open Sensing

 

2

 

Ignored

 

Detected

 

  Forced Open Monitoring

 

3

 

Ignored

 

Detected

 

  Exit Button Asserts Strike

 

4

 

Disabled

 

Enabled

 

  Pre-Alarm

 

5

 

Disabled

 

Enabled

 

  Keypad Alarm Response

 

6

 

Disabled

 

Enabled

 

  Forced Relock

 

7

 

Disabled

 

Enabled

 

  On Door Open

 

8

 

Disabled

 

Enabled

 

  On Door Close

 

9

 

Disabled

 

Enabled

 

  On Door Unlock Duration

 

10

 

Disabled

 

Enabled

 

* Picture Perfect 2.0 only