GE Security's Picture Perfect™ Flags and Values, Picture Perfect 1.5-2.0

This table shows the meanings and value meanings for all of the bit fields in the GE Security CASI Picture Perfect database.

Bit Meaning Bit Number Meaning When 0 Meaning When 1
alarm.flags
  Micro internal use only

0

Off

On

  Online

1

No

Yes

  Schedule Inhibit

2

No

Yes

  Auto Reset Outputs

3

No

Yes

  Manual Reset Outputs

4

No

Yes

  Duration Reset Outputs

5

No

Yes

  Immediate Reset Input

6

No

Yes

  Immediate Dial Required

7

No

Yes

area.flags
  Logical State

0

Offline

Online

  Physical

1

Disabled

Enabled

  Shunting

2

Disabled

Enabled

  Scheduling

3

Enabled

Disabled

  APB Enforcement

4

Normal

Passive

badge.flags
  Keypad Response

0

Disabled

Enable

  Card Trace

1

Disabled

Enabled

  Limited Usage

2

Reserved

Exhausted

  Tour Badge

3

No

Yes

  Temporary Badge*

4

No

Yes

inputs.flags
  Normally Closed

0

No (Normally Open)

Yes (Normally Closed)

  Input Enabled

1

No

Yes

input_group.flags
  Not Used

0

Not Used

Not Used

  Input Group State

1

Disabled

Enabled

  Open Condition

2

Ignored

Detected

  Short Condition

3

Ignored

Detected

  Broadcast State Changes

4

No

Yes

output.flags
  Normally Open

0

No

Yes

  Output Enabled

1

No

Yes

  Reset On Duration

2

No

Yes

  Reset On Input

3

No

Yes

permission.flags
  None

0

No

Yes

  Read Only - Show Number

1

No

Yes

  Read Only - Hide Number

2

No

Yes

  Issue - Show Number

3

No

Yes

  Issue - Hide Number

4

No

Yes

reader.type
  Badge Rdr

0

No

Yes

  Badge and Keypad

1

No

Yes

  Keypad Only Rdr

2

No

Yes

  Badge or Keypad

3

No

Yes

  ABP In Rdr

4

No

Yes

  APB Out Rdr

5

No

Yes

  For Future Use

6

0

 

  T/A In and Out

7

No

Yes

  T/A In Rdr

8

No

Yes

  T/A Out Rdr

9

No

Yes

  Authorization Required

10

No

Yes

  No Authorization Required

11

No

Yes

reader.flags
  Logical State

0

Offline

Online

  Physical State

1

Disabled

Enabled

  Shunting

2

Disabled

Enabled

  Scheduling

3

Enabled

Disabled

  Toggle

4

No

Yes

  Limited Usage

5

Disabled

Enabled

  Elevator Reader

6

No

Yes

routing.flags
  Monitor

0

No

Yes

  History

1

No

Yes

  Printer

2

No

Yes

door.flags
  State

0

Locked

Unlocked

  Scheduling

1

Enabled

Disabled

  Held Open Sensing

2

Ignored

Detected

  Forced Open Monitoring

3

Ignored

Detected

  Exit Button Asserts Strike

4

Disabled

Enabled

  Pre-Alarm

5

Disabled

Enabled

  Keypad Alarm Response

6

Disabled

Enabled

  Forced Relock

7

Disabled

Enabled

  On Door Open

8

Disabled

Enabled

  On Door Close

9

Disabled

Enabled

  On Door Unlock Duration

10

Disabled

Enabled

* Picture Perfect 2.0 only